Epoxy Repair
Two component, solvent free, chemically cured, mortar for repair, anchorage and building up.
Features & Advantages
- Never sagging
- Easy to apply, paste consistency
- It has high filler capacity
- Resistant to chemicals
- Solvent free
- Perfect adherence to concrete and steel
- Used both in horizontal and vertical applications.
Typical Application
- Concrete and stone walls
- High adherence to all kinds of metal and steel construction materials
- Fixing of earthquake dampers and balustrades in bridges and viaducts
- Fixing of anchoring elements
- Sealing of expansion joints tape.
Concrete Substrate Standards
Hardness R28 = 15 Mpa
Humidity = < %5
Temperature = +5°C ile +30°C
Relative humidity = < %85
For information about other substrates, please contact with our technical department.
Surface Preparation
All surfaces to be coated must be free of grease, oil, moisture, and other foreign matter. Surfaces should be dry, with release agents and laitance removed by abrasive blasting or acid etching. Surface salt is removed by high pressure water washing. Cement laitance, loose particles, mould release agents must be removed. Fill surface irregularities with relevant product.
PRIMING
Primer is not neccessary for surfaces cleaned properly.
APPLICATION
It is supplied in two-component kits which contain the proper ratio of ingredients. The entire contents of each container must be mixed together. Pot life of mixture is 40 minutes at +20˚C Higher temperatures will reduce pot life of the coating, lower temperatures will increase Don’t mix by manually. It is applied by spatula, trowel or cartridge gun. The prepared holes are filled with starting from the bottom. The application should be at least 2 mm and maximum 30 mm. The Anchoring should be placed in the EPOXY REPAIR which filled in the holes and width and the material should be owerfloved from the hole.
Cleaning of Tools
Tools should be cleaned with suitable solvent after application. Rollers are single use only
Packaging & Colors
Tools should be cleaned with suitable solvent after application. Rollers are single use only
3,75+ 1,25 Kg Sealed Pails – Grey Color
Shelf Life
Can be kept for minimum 12 months in the original sealed pails in dry places and at temperatures of +5˚C and +25 ˚C. Once opened, use it as soon as possible
Precaution
Can be kept for minimum 12 months in the original sealed pails in dry places and at temperatures of +5˚C and +25 ˚C. Once opened, use it as soon as possible
Apply in well-ventilated, no smoking areas, away from naked flames. In closed spaces use ventilators and carbon active masks. Hands and eyes must be protected with gloves and protective glasses. Case of eye contact, rinse eyes with plenty of water for the material. The MSDS (Material Safety Data Sheet) is available on request.